Harmony Thompson, Helen Lunt, Cate Fleckney and Steven Soule

Summary

An adolescent with type 1 diabetes and a history of self-harm, which included intentional overdoses and insulin omission, presented with an insulin degludec overdose. She had been commenced on the ultra-long-acting insulin, degludec, with the aim of reducing ketoacidosis episodes in response to intermittent refusal to take insulin. Insulin degludec was administered under supervision as an outpatient. Because it was anticipated that she would attempt a degludec overdose at some stage, the attending clinicians implemented a proactive management plan for this (and related) scenarios. This included long-term monitoring of interstitial glucose using the Abbott Freestyle Libre flash glucose monitor. The patient took a witnessed overdose of 242 units of degludec (usual daily dose, 32 units). She was hospitalised an hour later. Inpatient treatment was guided primarily by interstitial glucose results, with capillary and venous glucose tests used as secondary measures to assess the accuracy of interstitial glucose values. Four days of inpatient treatment was required. The patient was managed with high glycaemic loads of food and also intermittent intravenous dextrose. No hypoglycaemia was documented during the admission. In summary, while a degludec overdose may require several days of inpatient management, in situations where proactive management is an option and the dose administered is relatively modest, it may be possible to avoid significant hypoglycaemia. In addition, this case demonstrates that inpatient interstitial glucose monitoring may have a role in managing insulin overdose, especially in situations where the effect of the insulin overdose on glucose levels is likely to be prolonged.

Learning points:

  • Degludec overdoses have a prolonged effect on blood glucose levels, but if the clinical situation allows for early detection and management, treatment may prove easier than that which is typically needed following overdoses of a similar dose of shorter acting insulins.

  • Inpatient real-time interstitial monitoring helped guide management, which in this context included the prescription of high dietary carbohydrate intake (patient led) and intravenous 10% dextrose (nurse led).

  • Use of inpatient interstitial glucose monitoring to guide therapy might be considered ‘off label’ use, thus, both staff and also patients should be aware of the limitations, as well as the benefits, of interstitial monitoring systems.

  • The Libre flash glucose monitor provided nurses with low cost, easy-to-use interstitial glucose results, but it is nevertheless advisable to check these results against conventional glucose tests, for example, capillary ‘finger-stick’ or venous glucose tests.

Open access

Marcelo Maia Pinheiro, Felipe Moura Maia Pinheiro and Margareth Afonso Torres

Summary

Type 1 diabetes mellitus (T1DM) is a chronic disease characterized by autoimmune destruction of pancreatic beta cells and inadequate insulin production. Remission criteria in T1DM take into account serum levels of C-peptide and glycosylated hemoglobin, as well as the dose of insulin administered to the patient. However, remission of T1DM lasting longer than 1 year is rare. We describe here the cases of two young women who presented with positive glutamic acid decarboxylase (GAD) antibody and classic clinical manifestations of T1DM. Both patients had a prior history of Hashimoto’s thyroiditis. They were initially treated with a basal-bolus regimen of insulin (glargine and lispro/glulisine). Once their blood glucose levels were controlled, they were started on oral sitagliptin 100 mg and vitamin D3 5000 IU daily. After this therapy, both patients achieved clinical diabetes remission for 4 years, along with a decrease in anti-GAD antibody levels. These benefits were probably associated with immunological effects of these medications. Inhibition of dipeptidyl peptidase 4 (DPP-4) in animal models deregulates Th1 immune response, increases secretion of Th2 cytokines, activates CD4+CD25+FoxP3+ regulatory T-cells and prevents IL-17 production. Vitamin D3 also activates CD4+CD25+FoxP3+ regulatory T-cells, and these medications combined can improve the immune response in patients with new-onset T1DM and probably promote sustained clinical remission.

Learning points:

  • The use of sitagliptin and vitamin D3 in patients with new-onset type 1 diabetes mellitus (T1DM) may help decrease the daily insulin requirement by delaying beta cell loss and improving endogenous insulin production.

  • The use of sitagliptin and vitamin D3 in new-onset T1DM could help regulate the imbalance between Th17 and Treg cells.

  • Age 14 years or above, absence of ketoacidosis and positive C-peptide levels in patients with T1DM are good criteria to predict prolonged T1DM remission.

  • The determination of anti-GAD antibodies and C-peptide levels could be helpful in the follow-up of patients in use of sitagliptin and vitamin D3, which could be associated with prolonged T1DM clinical remission.

Open access

Betty Korljan Jelaska, Sanja Baršić Ostojić, Nina Berović and Višnja Kokić

Summary

Glycogen storage disease (GSD) type I is characterized by impaired production of glucose from glycogenolysis and gluconeogenesis resulting in severe hypoglycaemia and increased production of lactic acid, triglyceride and uric acid. The most common type, glycogenosis type Ia, demands a balanced, sufficient carbohydrate intake to preserve normal 24-h glycaemia. Insufficient intake of carbohydrates can cause hypoglycaemia, as the missing glucose-6-phosphatase enzyme cannot free the glucose stored as liver glycogen and nor is gluconeogenesis possible. The principle means of handling this disorder is to avoid starving by taking regular meals during the day and night. Such a dietary regimen could lead to obesity. Herein, we present the case of an adult patient with glycogenosis type Ia suffering from hyperuricaemia, dyslipidaemia and arterial hypertension. The accumulation of these cardiovascular risk factors could lead to the early onset of atherosclerosis, which should be postponed by contemporary methods of surveillance and treatment.

Learning points

  • Continuous subcutaneous glucose monitoring may be of value in every adult patient with GSD type I to evaluate the actual prevalence of eventual hypoglycaemic and hyperglycaemic episodes.

  • Good dietary management minimizes the metabolic abnormalities of the disease and decreases the risk of long-term complications.

  • Treatment of obesity in patients with GSD reduces the risk of earlier atherosclerosis and cardiovascular disease.